    摘要:

    [目的]比较椎板回植椎管重建内固定术对腰椎活动度范围(range of motion, ROM)的影响。[方法]分别建立腰椎 L2~4三维有限元模型,包括正常模型组、椎板切除组、椎板回植 H 形钛板固定组(H 形钛板组)、椎板回植 L 形钛板固定组(L 形钛板组) 和椎板回植两孔钛板固定组 (两孔钛板组)。在 L2椎体上施加 10 N · m 的应力,测量 6 种自由度下 L2/3和 L3/4节段 ROM。[结果] 总体方面,5 组模型的 6 种自由度比较,L2/3 ROM 由大至小均依次为:左侧弯>前屈>右侧变>后伸>右旋>左旋, L3/4为:前屈>左侧弯>右侧变>后伸>右旋>左旋,总体差异均有统计学意义 (P<0.05)。 6 种自由度的五组模型比较,L2/3和 L3/4 的 ROM 由大至小均依次为:椎板切除组>两孔钛板组> L 形钛板组> H 形钛板组>正常模型组,总体差异均有统计学意义 (P< 0.05)。左弯、右弯、左旋和右旋状态下,H 形钛板的 ROM 显著小于 L 形钛板组和两孔钛板组(P<0.05)。[结论]椎管重建可有效减少椎板切除所致的异常节段的活动度增加,且 H 形钛板固定重建椎管在抗弯曲和旋转时,其生物力学稳定性要优于 L 型和两孔钛板。

    Abstract:

    [Objective] To compare the influence of lamina replantation with different internal fixations for spinal canal reconstruction on segmental range of motion (ROM) of the lumbar spine. [Methods] The lumbar L2~4 three-dimensional finite element models were estab- lished respectively, including normal model group (NM group) , laminectomy group (LE group) , laminectomy and H-shaped titanium plate fixation group (H-plate group), laminectomy and L-shaped titanium plate fixation group (L-plate group) and laminectomy and two-hole tita- nium plate fixation group (TH plate group) . A 10 Nm loading was applied to the L2 vertebral body, the ROMs of L2/3 and L3/4 segments in six degrees of freedom were measured. [Results] In terms of overall comparison among the 6 degrees of freedom, the ROMs of L2/3 were ranked in descending order: left bending > forward flexion > right bending > extension > right rotation > left rotation, with statistically significant overall difference in all the 5 model groups (P<0.05) . The ROMs of L3/4 were ranked in descending order: forward flexion > left bending > right bending > extension > right rotation > left rotation, with statistically significant overall difference in all the 5 model groups (P<0.05) . However, in terms of overall comparison among the 5 model groups, the ROM of L2/3 and L3/4 were arranged in descending order of: LE group > TH plate group > L-plate group > H- plate group > NM group, which all were statistically significant in 6 degrees of freedom (P< 0.05) . In the left bending, right bending, left and right rotations, the ROM of H-plate group had significantly lower ROMs than that of Lplate group and TH plate group (P<0.05) . [Conclusion] The lamina replantation with different internal fixations for spinal canal reconstruc- tion does effectively reduce the abnormal increase of segmental ROMs caused by laminectomy. Of them, H-shaped titanium plate fixation achieves better stability than L-shaped plate and two-hole titanium plate in terms of resistance of bending and rotation.

    参考文献
    相似文献
    引证文献
引用本文

陈建民,徐院生,郭兴锋,等. 椎管重建对腰椎活动度影响的有限元分析[J]. 中国矫形外科杂志, 2022, 30 (14): 1287-1292. DOI:10.3977/j. issn.1005-8478.2022.14.08.
CHEN Jian-min, XU Yuan-sheng, GUO Xing-feng, et al. Impact of internal fixations for lumbar canal reconstruction on segmental range of motion: a finite element analysis[J]. Orthopedic Journal of China , 2022, 30 (14): 1287-1292. DOI:10.3977/j. issn.1005-8478.2022.14.08.

复制
文章指标
  • 点击次数:
  • 下载次数:
  • 引用次数:
历史
  • 收稿日期:2021-08-01
  • 最后修改日期:2022-02-21
  • 录用日期:
  • 在线发布日期: 2023-06-29
  • 出版日期: