胸腰段椎弓根置钉的术中三维实时导航
作者:
作者单位:

作者简介:

刘彬,副主任医师,脊柱外科方向,(电话)18669337908,(电子信箱)wdzglb@163.com

通讯作者:

中图分类号:

R687

基金项目:

第七批全国老中医药专家传承项目(编号:国中医药人教函[2022]76 号)


Intraoperative three-dimensional real-time navigation for thoracolumbar pedicle screw placement
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的]评估术中三维实时导航系统辅助植钉技术的影像结果。[方法]2016 年 3 月—2019 年 3 月,62 例患者接受胸腰椎椎弓根钉固定术,术中随机选择一侧采用三维实时导航置钉,另一侧采用徒手置钉。采用 Rampersaud 的标准对影像椎弓根钉置入的准确性进行评估比较。[结果] 62 例患者共置钉 204 枚。胸椎 62 枚,置钉准确率导航辅助侧为 93.55% (29/ 31),徒手侧为 77.42% (24/31),两侧差异有统计学意义 (P<0.05)。腰椎 142 枚,置钉准确率导航辅助侧为 97.18% (69/71), 徒手侧为 80.28%(57/71),差异有统计学意义(P<0.05)。[结论]胸腰椎弓根置入采用三维实时导航系统辅助技术,显著提高了置钉的精确性。

    Abstract:

    [Objective] To evaluate the imaging outcomes of intraoperative three- dimensional real-time navigation assisted pedicle screw placement. [Methods] From March 2016 to March 2019, 62 patients underwent thoracolumbar pedicle screw fixation. During the op- eration, one side was randomly selected to use three-dimensional real-time navigation screw placement, while the contralateral side had screw placed by conventional freehand technique. The accuracy of pedicle screw placement on images was evaluated and compared be- tween the two sides. [Results] A total of 204 screw were placed in 62 patients. Of the 62 screws in thoracic vertebrae, the screw placement accuracy rate was 93.55% (29/31) on the navigation assisted side, while 77.42% (24/31) on the freehand side, which was statistically signifi- cant (P<0.05) . Of the 142 screws in lumbar vertebrae, the accuracy of screw placement was 97.18% (69/71) on the navigation assisted side, whereas 80.28% (57/71) on the freehand side, with a statistically significant difference between the two sides (P<0.05) . [Conclusion] The intraoperative three-dimensional real-time navigation does considerably improve the accuracy of pedicle screw placement

    参考文献
    相似文献
    引证文献
引用本文

刘彬,姜泽威,李佳佳,等. 胸腰段椎弓根置钉的术中三维实时导航[J]. 中国矫形外科杂志, 2022, 30 (20): 1914-1917. DOI:10.3977/j. issn.1005-8478.2022.20.21.
LIU Bin, JIANG Ze-wei, LI Jia-jia, et al. Intraoperative three-dimensional real-time navigation for thoracolumbar pedicle screw placement[J]. Orthopedic Journal of China , 2022, 30 (20): 1914-1917. DOI:10.3977/j. issn.1005-8478.2022.20.21.

复制
文章指标
  • 点击次数:
  • 下载次数:
  • 引用次数:
历史
  • 收稿日期:July 21,2021
  • 最后修改日期:August 25,2022
  • 录用日期:
  • 在线发布日期: June 29,2023
  • 出版日期: