Comparison of X-ray and MRI measured fibular inclination angles of the proximal tibiofibular joint
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    [目的] 探讨重建膝关节磁共振 (magnetic resonance imaging, MRI) 图像测量近端胫腓关节 (proximal tibiofibular joint, PTFJ) 倾斜角的可行性与可靠性。[方法] 共 35 例内侧间室 OA 患者 (35 膝) 纳入本研究,行 MRI 测量腓骨倾斜角 (MRI measured fibular inclination angle, M-FIA) 和 X 线测量腓骨倾斜角 (X-ray measured fibular inclination angle, X-FIA) 测量, 评估 M-FIA 的信度,以及 M-FIA 与 X-FIA 之间的差异,采用 Bland-Altmann 分析法评估两者的一致性。[结果]M-FIA 测量的观察者内与观察者间组内相关系数(intraclass correlation coefficient, ICC)分别为 0.97 和 0.90,为一致性优异信度优异。X-FIA 和 M-FIA 两种测量方法的测量值间差异无统计学意义 [(26.9±7.6)° vs (26.6±7.5)°, P=0.244]。M-FIA 与 X-FIA 的 95%一致性界限为 (-0.3±2.8)°。[结论]重建膝关节 MRI 图像来测量 PTFJ 倾斜角是可重复的技术。M-FIA 与 X-FIA 可以相互替代。

    Abstract:

    [Objective] To investigate the feasibility and reliability of fibular inclination angles of proximal tibiofibular joint (PTFJ) mea- sured by magnetic resonance imaging (MRI) reconstruction of the knee. [Methods] A total of 35 patients (35 knees) with medial knee osteoar- thritis were included in this study. The MRI measured fibular inclination angle (M-FIA) and X-ray measured fibular inclination angle (XFIA) were conducted to present the inclination of PTFJ. The reliability of M-FIA and the differences between M-FIA and X-FIA were evalu- ated, and the consistency of the two measures was assessed by Bland-Altmann analysis. [Results] The intraclass correlation coefficient (ICC) of intra-observer and inter-observer reliability measured by M-FIA were of 0.97 and 0.90, respectively, indicating excellent consistency re- liability. There was no significant difference between the measured values of X-FIA and M-FIA [(26.9±7.6)° vs (26.6±7.5)°, P=0.244]. In term of Bland-Altmann analysis, the 95% agreement limit between M-FIA and X-FIA was of (-0.3±2.8)°. [Conclusion] The knee MRI re- construction used to measure PTFJ inclination is a reproducible technique. M-FIA and X-FIA can be substituted for each other.

    参考文献
    相似文献
    引证文献
引用本文

黄承,陆志剀,程继伟,等. 近端胫腓关节倾斜角的X线与MRI测量对比△[J]. 中国矫形外科杂志, 2023, 31 (19): 1812-1814. DOI:10.3977/j. issn.1005-8478.2023.19.17.
HUANG Cheng, LU Zhi-kai, CHENG Ji-wei, et al. Comparison of X-ray and MRI measured fibular inclination angles of the proximal tibiofibular joint[J]. Orthopedic Journal of China , 2023, 31 (19): 1812-1814. DOI:10.3977/j. issn.1005-8478.2023.19.17.

复制
文章指标
  • 点击次数:
  • 下载次数:
  • 引用次数:
历史
  • 收稿日期:June 27,2022
  • 最后修改日期:August 29,2023
  • 录用日期:
  • 在线发布日期: October 26,2023
  • 出版日期: